SATA Bus Interface and ATA Commands
Maxtor QuickView 400/500GB Serial ATA Hard Disk Drive 5-7
53
15-3: Reserved
2:
1 = the fields reported in word 88 are valid.
0 = the fields reported in word 88 are not valid
1:
1 = the fields reported in words (70:64) are valid.
0 = the fields reported in words (70:64) are not valid
0: Obsolete
54-58 Obsolete
59
15-9: Reserved
8: 1 = Multiple sector setting is valid
7-0: xxh = Current setting for number of sectors that shall be transferred per
interrupt on R/W Multiple command
60-61 Total number of user addressable sectors
62 Obsolete
63
15-11: Reserved
10:
1 = Multiword DMA mode 2 is selected.
0 = Multiword DMA mode 2 is not selected
9:
1 = Multiword DMA mode 1 is selected.
0 = Multiword DMA mode 1 is not selected
8:
1 = Multiword DMA mode 0 is selected.
0 = Multiword DMA mode 0 is not selected
7-3: Reserved
2: 1 = Multiword DMA mode 2 and below are supported
1: 1 = Multiword DMA mode 1 and below are supported
0: 1 = Multiword DMA mode 0 is supported
64
15-8: Reserved
7-0: PIO modes supported
65
Minimum Multiword DMA transfer cycle time per word
15-0: Cycle time in nanoseconds
66
Manufacturer’s recommended Multiword DMA transfer cycle time
15-0: Cycle time in nanoseconds